PB0-200 Exam
APC NCPI Design
- Exam Number/Code : PB0-200
- Exam Name : APC NCPI Design
- Questions and Answers : 115 Q&As
- Update Time: 2011-10-24
- Testing Engine (SoftWare Version): $ 50.00
- PDF (Printable Version) Price: $15.00
Note: After purchase, we will send questions within 24 hours.
Free PB0-200 Demo Download
ultraexam offers free demo for APC PB0-200 exam (APC NCPI Design). You can check out the interface, question quality and usability of our practice exams before you decide to buy it. We are the only one site can offer demo for almost all products.
Download PB0-200 Exam Testing Engine
Exam Description
It is well known that PB0-200 examtest is the hot exam of APC certification. ultraexam offer you all the Q&A of the PB0-200 real test . It is the examination of the perfect combination and it will help you pass PB0-200 exam at the first time!
Why choose ultraexam PB0-200 braindumps
Quality and Value for the PB0-200 Exam
100% Guarantee to Pass Your PB0-200 Exam
Downloadable, Interactive PB0-200 Testing engines
Verified Answers Researched by Industry Experts
Drag and Drop questions as experienced in the Actual Exams
Practice Test Questions accompanied by exhibits
Our Practice Test Questions are backed by our 100% MONEY BACK GUARANTEE.
ultraexam PB0-200 Exam Features
Quality and Value for the PB0-200 Exam
ultraexam Practice Exams for APC PB0-200 are written to the highest standards of technical accuracy, using only certified subject matter experts and published authors for development.
100% Guarantee to Pass Your PB0-200 Exam
APC PB0-200 Downloadable
PB0-200 Downloadable, Interactive Testing engines
Ultraexam.com PB0-200 free web demo:
Exam : APC PB0-200
Title : APC NCPI Design
1. What is a common application for 2-post racks?
A. telecom
B. server room
C. remote office
D. IT data center
Answer: A
2. A site requires redundant power feeds to single-corded servers. What is a possible redundant configuration?
A. two single-module UPSs feeding one rack-mount Automatic Transfer Switch and one outlet strip per rack
B. two single-module UPSs each feeding dual-panel distribution boards, which in turn feed two outlet strips per rack
C. two single-module UPSs each feeding two outlet strips per rack; plugging half the servers in one strip and the other half in another strip
D. two single-module UPSs each fed from separately derived utility sources; sources that come from one of two independent utility substations
Answer: A
3. What are two reasons why a fully rated UPS (output kW = output kVA) is more compatible with today's IT loads than an 80%-rated UPS (output kW = output kVA at a 0.8 power factor)? (Choose two.)
A. 80%-rated UPSs are more efficient.
B. Today's IT loads are power-factor corrected.
C. Fully-rated UPSs have superior output voltage control.
D. Fully-rated UPSs make it less likely to undersize the UPS.
E. Today's IT loads lock up when powered by an 80%-rated UPS.
Answer: BD
4. How do you achieve full system redundancy in a precision air conditioning system?
A. install multiple air conditioning systems in an N+1 configuration
B. install a properly-sized DX air cooled unit with chilled water back-up
C. install a properly-sized air conditioning unit with redundant compressors
D. install Building System cooling (comfort cooling) with an air conditioning unit in standby
Answer: A
5. If a company requests that its UPS output power be distributed to the racks through an isolation transformer, what are they trying to do?
A. decrease the cable size to the load
B. increase the efficiency of the system
C. increase availability throughout the data center
D. prevent electrical noise from locking up the servers
Answer: D